Xperia - Stainless Steel Coronary Stent System
Stent & balloon induced acute mechanical arterial injury during expansion is an important determinant of restenosis. The cellular signaling mechanisms that result in platelet deposition, thrombus formation, & smooth muscle cell proliferation begin in response to arterial injury. It has been shown that deep injury to the media & superficial injury to the endothelium occur during stent expansion. Stent implantation imparts extreme vascular strain & focal mechanical injury to the vessel wall ranging from denudation of the endothelial cell mono layer, to progressive laceration of the deeper vascular structures. The amount of injury inflicted by the stent and balloon is a function of stent geometry.
Xperia coronary stent is the next generation Uniform sinusoidal cell geometry stent, designed to minimize stent induced arterial injury. It is carefully designed to incorporate controlled stent expansion characteristics, better stent-artery compliance, superior acute gain, optimum cell sizes & shape, lower strut thickness and high flexibility.
 

Unique Design Features

Unique edge design offers controlled stent expansion.

Edge injuries are caused by both stent edge flaring during expansion & balloon "Dog Boning". Conventional stent designs expand as "Edge First Expansion" resulting in injury at the edges. The stent balloon mismatch also causes injury at the edges due to "Dog Boning" effect. Xperia incorporates wide closed cells at the stent edges that will minimize edge flaring & knife edge focal injury during expansion. Also the stent & balloon is precisely matched to minimize "Dog Boning" effect.
 

Optimum cell size & shape

Generally during stent expansion, due to the intra cellular balloon protrusion, the expansion energy from the balloon is transferred to the arterial wall causing injuries. This is cell size & shape dependent. Xperia has optimum cell size & shape to minimize injuries.
 

Lower strut thickness

Xperia has thin struts to minimize focal mechanical injury to the vessel wall.
 

Better stent artery compliance

During the stent expansion, artery experiences extreme strain. Greater the strain greater is the injury. Xperia is designed to minimize arterial strain due to stent-artery compliance mismatch.
 

Superior acute gain-more vessel area

Xperia tends to recoil less than 2% when fully expanded, whereby offering superior acute & more vessel area.
 

High flexibility & lower crossing profile to address complex anatomies.

Lower strut thickness offers lower crossing profile & multi axial high flexibility while negotiating complex anatomies. Vessels do not tend to straighten after the stent expansion.

designed for optimal strength and flexibility
 

Technical Specification of Xperia 316L Stainless Steel Stent System

Available Stent Length (mm) 8, 13, 16, 19, 24, 29, 32, 37, 40
Available Stent Diameter (mm) 2.25,2.50,2.75,3.00,3.50,4.00,4.50
Stent Material A medical grade 316L Stainless Steel alloy  
Stent Strut thickness 100 µm
Stent Strut Width Proximal/Distal Cell: 100 µm Straight connector at proximal/Distal cell: 100 µm Mid Cell: 80 µm Connector: 60 µm
Balloon Delivery System Rapid Exchange
Hydrophilic Coating On the distal and proximal shaft of balloon delivery system.
Delivery System Usable Length 140 cm
Balloon Inflation Pressure Nominal Pressure (NP): 8 atm
Rated Burst Pressure (RBP): 16 atm*
(*RBP for 4.5mm-14 atm)
Stent Length        Crossing Profile
2.25 mm                 0.85 mm
2.50mm                  0.90 mm
2.75mm                  0.95 mm
3.00 mm                1.10 mm
3.50 mm                1.15 mm
4.00 mm                1.20 mm
4.50 mm                1.27 mm
Guiding catheter Inner Diameter 5 Fr (0.056”) (1.4 mm) Compatible
Catheter Outer Shaft Diameter 2.70 Fr Proximally, 1.95 Fr Distally
Balloon Overhang: <0.5mm
Dogboning:  <0.3mm
Max. Guide wire 0.014 inch
 

Ordering Information

Diameter
(mm)
8
13
16
19
24
29
32
37
40
2.25
XP2.2508
XP2.2513
XP2.2516
XP2.2519
XP2.2524
XP2.2529
XP2.2532
XP2.2537
XP2.2540
2.50
XP2.5008
XP2.5013
XP2.5016
XP2.5019
XP2.5024
XP2.5029
XP2.5032
XP2.5037
XP2.5040
2.75
XP2.7508
XP2.7513
XP2.7516
XP2.7519
XP2.7524
XP2.7529
XP2.7532
XP2.7537
XP2.7540
3.00
XP3.0008
XP3.0013
XP3.0016
XP3.0019
XP3.0024
XP3.0029
XP3.0032
XP3.0037
XP3.0040
3.50
XP3.5008
XP3.5013
XP3.5016
XP3.5019
XP3.5024
XP3.5029
XP3.5032
XP3.5037
XP3.5040
4.00
XP4.0008
XP4.0013
XP4.0016
XP4.0019
XP4.0024
XP4.0029
XP4.0032
XP4.0037
XP4.0040
4.50
XP4.5008
XP4.5013
XP4.5016
XP4.5019
XP4.5024
XP4.5029
XP4.5032
XP4.5037
XP4.5040
  Download Brochure
Indian FDA approved
Manufacturing License Number - G/28/1395
|
|
|
|
|
|
All rights reserved by Nano Therapeutics Pvt Ltd @ 2014